{"title":"Cardiac Marker","description":"\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eCardiac markers are \u003c\/span\u003e\u003cb\u003ebiochemical substances released into the blood when the heart muscle is damaged\u003c\/b\u003e\u003cspan class=\"s1\"\u003e. They are widely used for the \u003c\/span\u003e\u003cb\u003eearly diagnosis, risk assessment, and monitoring of cardiac events\u003c\/b\u003e\u003cspan class=\"s1\"\u003e, especially \u003c\/span\u003e\u003cb\u003emyocardial infarction (heart attack)\u003c\/b\u003e\u003cspan class=\"s1\"\u003e. Common cardiac markers include \u003c\/span\u003e\u003cb\u003eTroponin I \u0026amp; T (most specific and sensitive), CK-MB, Myoglobin, and BNP\/NT-proBNP\u003c\/b\u003e\u003cspan class=\"s1\"\u003e. Measurement of cardiac markers helps clinicians \u003c\/span\u003e\u003cb\u003econfirm cardiac injury, guide treatment decisions, and evaluate patient prognosis\u003c\/b\u003e\u003cspan class=\"s1\"\u003e in emergency and critical care settings.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"troponin-i-ctnt","title":"Troponin-I (cTnT)","description":"\u003cp\u003e\u003cspan\u003eCardiac Troponin I (cTnI) is a protein found in cardiac muscle with a molecular weight of 22.5 kDa. Troponin I is part of a three subunit complex comprising of Troponin T and Troponin C. Along with tropomyosin, this structural complex forms the main component that regulates the calcium sensitive ATPase activity of actomyosin in striated skeletal and cardiac muscle. After cardiac injury occurs, Troponin I is released into the blood 4-6 hours after the onset of pain. The release pattern of cTnI is similar to CK-MB, but while CK-MB levels return to normal after 72 hours, Troponin I remains elevated for 6-10 days, thus providing for a longer window of detection for cardiac injury. The high specificity of cTnI measurements for the identification of myocardial damage has been demonstrated in conditions such as the perioperative period, after marathon runs, and blunt chest trauma. cTnI release has also been documented in cardiac conditions other than acute myocardial infarction (AMI) such as unstable angina, congestive heart failure, and ischemic damage due to coronary artery bypass surgery. Because of its high specificity and sensitivity in the myocardial tissue, Troponin I has recently become the most preferred biomarker for myocardial infarction. The Cardiac Troponin I (cTnI) Rapid Test is a simple test that utilizes a combination of anti-cTnI antibody coated particles and capture reagent to detect cTnI in whole blood, serum or plasma. The minimum detection level is 0.5ng\/mL.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eCheck \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0973\/1827\/3323\/files\/ENCORE_-_Cardiac_Troponin_I_-_EN_-_VER_01.pdf?v=1767253997\" rel=\"noopener\" style=\"color: rgb(255, 42, 0);\" target=\"_blank\"\u003eHERE \u003c\/a\u003e\u003c\/span\u003eInstructions For Use (Pack Insert)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Enssure","offers":[{"title":"10 TESTS","offer_id":51679670763819,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/1827\/3323\/files\/CTNT-02.jpg?v=1766737440"},{"product_id":"nt-probnp","title":"NT-proBNP","description":"\u003cp\u003e\u003cspan\u003eThe N-terminal of the prohormone brain natriuretic peptide (NT proBNP) is a 76 amino acid N-terminal inactive protein that is cleaved from proBNP to release brain natriuretic peptide. Both BNP and NT proBNP levels in the blood are used for screening, diagnosis of acute congestive heart failure (CHF) and may be useful to establish prognosis in heart failure, as both markers are typically higher in patients with worse outcome. The plasma concentrations of both BNP and NT proBNP are also typically increased in patients with asymptomatic or symptomatic left ventricular dysfunction and is associated with coronary artery disease and myocardial ischemia. The NT-proBNP Rapid Test is a simple test that utilizes a combination of anti-NTproBNP antibody coated particles and capture reagents to qualitatively detect NTproBNP in whole blood, serum or plasma. The minimum detection level is 0.45ng\/mL.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eCheck \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0973\/1827\/3323\/files\/ENCORE_-_NT-proBNP_-_EN_-_VER_02.pdf?v=1767249576\" rel=\"noopener\" style=\"color: rgb(255, 42, 0);\" target=\"_blank\"\u003eHERE \u003c\/a\u003e\u003c\/span\u003eInstructions of Use (Pack Insert)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Enssure","offers":[{"title":"10 TESTS","offer_id":51679650513195,"sku":null,"price":1500.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/1827\/3323\/files\/NT-02.jpg?v=1766735643"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/1827\/3323\/collections\/CAR.jpg?v=1766582455","url":"https:\/\/shop.encorebiomedicals.com\/collections\/cardiac-marker.oembed","provider":"Encore Biomedicals ","version":"1.0","type":"link"}